Popularize Hot: rack  Necklace  forging  bitumen  led  aluminum  tools  abrasives  hoe  hinge 

500/8D Pressure Switches 01

Click to view the original image
 
Packing: box
Unit Price: negotiate face to face
Min.Order:
Supply:
Delivery: Shipment within 3 days since the date of payment
Address: China(Mainland)
Valid until: Never Expire
Updated on: 2014-03-05 21:30
Hits: 537
Enquiry
 
Company Details
Details

The Sensor of Switch is Diaphragm type, it can be suitable for air, gas such neutral gas and water, hydraulic oil, light fuel, lube and other fluid medium which would not exert corrosion to pressure sensor material. The Set Point of the Switch is adjustable, the adjustable range is from 0.02 Mpa to 3Mpa. Technical Performance: Working Viscosity <1x10-3m2/s Switching Elements: Microswitches Protection Class of Enclosure: Ambient temperature: -20º C~50º C Medium Temperature: 0~90º C Mounting Position: Pressure connection virtically downward (an angle of 15 is allowable). Anti-Vibration: Max. 100m/s2 Repeatablity Error: ≤ 1.5% Electrical rating: AC 220V, 6A(Resistance) Characteristic: Mini Structure, good Anti-vibration Remarks: *)In the practice, even the temporal peak value of pressure, should no exceed the Max. Allowable Pressure. **) I--the connection is inner screwed, P--the connection is flange The Adjustment for Dead Band Non-Adjustable Switches Choose Order No. 0820750 Switch, a contact signal is required to be generated when pressure fall to 1.5Mpa( the Decreasing Set Point) 1) Loose the locknut, screw the Hi-Pressure Port into the threaded connection of Checkout Test Set. If the connection type of the switch is flange, then 2) Open the front cover of the switch, let the cable pass through electrical connection and link to the terminal, link another end to the multimeter. 3) Add the pressure to 0.5Mpa, this value can be read from the standard pressure gauge. 4) Clockwise rotate the Set Point Adjusting bolt, to make the Set Point calibration change from small to bigl, until it switchs at 1.5Mpa. 5) Screw the locknut, adjust the pressure of the testing desk, to make the pressure change up and down around 1.5Mpa, to test if it switches at 1.5Mpa when pressure is falling. Its correspondent Increasing Set Point just to be 1.5Mpa plus Dead Band 0.15Mpa(approximate), thus 1.65Mpa Selection and Installation of the Switches The Set Point must be within the aAdjustable Range, Dead Band is expressed as Typical at mid-range. Normally it is the 20% to80% of the Ajustable Range. If the switches are outdoor application, sufficient protections are necessary, for the severe variation of the ambient temperature, radiation of the sunlight, permeation of the corrosive gas or water, will influence the life of the switches. Choose suitable outer diameter cable, and screw the lucknut to avoid the permeatation of dust and water. Regarding those controlled fluid medium with peak value of pressure and plusation pressure, a damper can be installed at the connection, to eliminate negative influence The On-Off current should not exceed the Rating (when the contacts act frequently, the current better not to exceed the 60% of the Rating. ) During the process of installation or disassembly, a spanner MUST be used to clip and tighten the connection part of the sensor, to prevent the housing and the Hi-pressure &Lo-pressure connections become flexible. If the connection of sensor is Female Thread, the depth for the pipe to screw in should not greater than 12mm.

More>Our Others Products
Intelligent Digital Pressure Switch (TXZ) Oil Pressure Switch (YWK-18D) Switch TXK-101 Digital Pressure Switch (TXZ) High Pressure Switch (YTK-18H) 530/7DDP Low Differential Pressure Switch Pressure Switch LPK-50 Pressure Switch (505/18D)
Home  |  Terms & Conditions  |  About us  |  Contact us  |  Agreement  |  Copyright Policy  |  Sitemap  |  Ranking promotion  |  Advert Server  |  Integral Exchange  |  Guestbook  |  RSS  |  Whistle-blowing