Pressure Switches (YWK-18D)

 
 
单价 面议对比
询价 暂无
浏览 1046
发货 China(Mainland)付款后3天内
Packing Craton
过期 长期有效
更新 2014-03-05 21:31
 
联系方式
加关注0

CHANGZHOU TIANLI CONTROLLER MANUFACTURING CO., LTD.

VIP会员第13年
资料未认证
保证金未缴纳
  • China(Mainland)
  • 上次登录 2014-03-05
  • Mrs. Sophia Zhang (先生)  
详细说明

The sensor of Switches is Diaphragm type, it has advantages as Hi-pressure endurable, long working life, compact structure. The enclosure is made of high-class stainless materials, solid and durable. Working Viscosity: <1x10-3m2/s Ambient temperature: :-25º C~+55º C Medium Temperature: -25º C~+80º C Mount Position: Pressure connection virtically downward (15° Inclination is allowed) Protection Class of Enclosure: IP65 Anti-Vibration: Max: 100m/s2 Repeatablity Error: ≤ 2% Working Life: 1x105 circle Electric Rating: AC 220V 6A(resistance) Weight: 0.23kg Remarks: In the practice, even the temporal peak value of pressure, should no exceed the Max. Allowable Pressure. Special requirements on Dead Band or Connection can be designed customized The Adjustment for Set Point [Example] Choose Switch with Pressure Range from 2.4Mpa to 24Mpa, a contact signal is required to be generated when pressure falls to 15Mpa(The Decreasing Set Point), see steps as following: To screw the switch into connection of Oil Pressure Checkout Test Set. Exert pressure on it for 2 minutes simulate its practical working situation, thereafter to make the setting. Link the Out-put lead with Multimeter. Screw-off the screws on the housing. Add the pressure to 15Mpa, this value can be read from the standarded pressure gauge. Use socket screwwrench (Φ 3mm), clockwise rotate the Set-point Adjusting Bolt, to make the Set-Point become bigger, until it switches at 15Mpa. Vering the testing pressure to make it change up and down arround 15Mpa, check if the Switch switches at 15Mpa when pressure falls, this value is the Decreasing Set Point need to be set, the correspondent Increasing Set Point is within 16.9Mpa to 18Mpa. Tighten the Locknut. While removing the cover, please do not touch the components inside the switches. The Set Point must be within the aAdjustable Range, Dead Band is expressed as Typical at MID-range. Normally it is the 20% to80% of the Ajustable Range. If the switches are outdoor application, sufficient protections are necessary, for the severe variation of the ambient temperature, radiation of the sunlight, permeation of the corrosive gas or water, will influence the life of the switches. During the process of installation or disassembly, a spanner MUST be used to clip and tighten the sensor, absolutely avoid the countermovent between the sensor and housing of the switches(please refer to the drawings)

举报收藏 0
更多>本企业其它产品
Intelligent Digital Pressure Switch (TXZ) Oil Pressure Switch (YWK-18D) Switch TXK-101 Digital Pressure Switch (TXZ) High Pressure Switch (YTK-18H) 530/7DDP Low Differential Pressure Switch Pressure Switch LPK-50 Pressure Switch (505/18D)
Home  |  Terms & Conditions  |  About us  |  Contact us  |  Agreement  |  隐私政策  |  Copyright Policy  |  Sitemap  |  Promotion  |  Advertisement  |  Gift  |  Guestbook  |  RSS  |  Report  |  浙ICP备2022009825号-2