Adopts horizontal box and downwords light optics design, suitable for intermediate testing and final testing of solar module. Adopts pulses Xeon-lamp as Simulation photosource, ceramic cavity reflection device realize high uniformity of the simulated sunlight, aviod the influence caused by temperature from steady-state sun simulator to the testing result Simulator light spectrum meet IEC60904-9 spectral irradiance distribution of A-level requirements Light intensity 100mW/cm (adjustment range: 70-120mW/cm) Advanced precision constant light control technology, radiation instability: : ± 1(Agrade) Pulsed xenon lamp imported from Germany, with a special filtre optical component, ensure test source spectrum correctly, long lifetime of use Counting function of flashes(Zero reset when repalcement) Application and Market Specially uesd in testing mono-crystalline silicon, poly-crystalline silicon, amorphous-crystalline silicon solar cell module.Type specification SMT-A SMT-B SMT-F Spectrum Meet the IEC60904-9 requirement (A grade) Light intensity 100mW/cm(adjustment range: 70-120mW/cm) Nonuniformity ≤ ± 2% ≤ ± 3% ≤ ± 2% Instablity ≤ ± 2% ≤ ± 3% ≤ ± 2% Consistency of test result ≤ ± 0.5% ≤ ± 1% ≤ ± 0.5% Electricity properties testing error ≤ ± 1% ≤ ± 2% ≤ ± 1% Single flash time 10ms 10ms 10ms Test Area 1200mm× 2000mm Test range 10W~300W Test Voltage 1V~10V(Resolution 1mV) Test current 100mA-20A(Resolution 1mA) Test parameter Isc Voc Pmax Vm Im FF EFF Temp Data acquisition quality 8000data point (I-V Curve)