Self-developed X-ray Fluorescence analysis system is in seamless Connection with DCS system or QCX system built on the OPC SERVER and OPC framework. The configuration can be changed to QCS server. - All Chinese operating system makes the instrument easy to Manipulate. - The all-spectrum analytical technique is created by us. It traces and Corrects every spectrum in real time, which greatly improves the Repeatability and stability of quantitative analysis. - There are two ways of qualitative analysis: Empirical coefficient method And theoretical a-coefficient method, among which theoretical a-Coefficient method reduces the number of standard sample greatly While retains the accuracy of qualitative analysis. - Analysis data treatment, linear fitting, and various matrices correction - The characteristic value can be calculated according to analysis Values. - Man-machine interaction allows for setting and modifying the Parameters. - Timely output of analysis data and report - Complete self-diagnosis measures Technical Specifications - Temperature control accuracy of constant temperature chamber: Setting value36° C0.1° C. - X-ray tube: 400W thin Be end window X-ray tube made by Varian Company. Rh anode (optional) - High voltage supply: 200W (50KV4mA). 12-hour tube voltage & tube Current stability: Better than 005 %. - Measurable elements: 10 arbitrary elements from Na to U. - Detector: Gas proportional detector plus sealed proportional detector; 10 paths of 1024-channel independent pulse height analyzer - Vacuum system: Independent pumping station is easy for Maintenance. The highest vacuum degree is lower than 5 Pa. - Flow gas system: High sophisticated flow density stabilizer with Stability up to ± 0.003 KPa. - AC220V power supply: 1kVA AC purified stabilized voltage power Supply - Analysis accuracy: On 1(24 hours, per cent) ≤ 0.05 %. - Test time of single sample: (including the time of changing the sample And pumping the vacuum)≤ 3 - 5 minutes - Analysis software: There are two ways of quantitative analysis: Empirical coefficient method and theoretical a-coefficient method. As There is an adoption of all-spectrum detection technique, the Repeatability and stability of quantitative analysis is greatly improved. The software has all-round self-diagnosis measures. The built-in RS- 232 serial communication protocol, TCP / IP protocol (Socket based S/ C) and OPC protocol (OPC server) enable data sharing with DCS or QCS system. Standard configurations - 200W high-voltage power - 400W Be end window X-ray tube - Gas flow proportional detector + sealed proportional detector - 10 paths of 1024-channel independent pulse height analyzer - Independent vacuum pumping structure - High sophisticated flow density stabilizer - Multi-channel MCA real-time detection system - 1kVA AC purified stabilized current