12V24W metal enclosure power for advertising machineQuick Detail:Input Voltage:100V~240V AC 50/60HZInput Voltage Range:90V~265V ACInput Frequency Range:47~63HzOutput Voltage Range: DC 5.0V ~ 24VOutput Current Range: 0 ~ 4.0ADimension: 84*58*38MM (L*W*H)Environment:Working Temp:-20 ~ +70Working Humidity:20 ~ 90%RH non-condensingStorage Temp, Humidity:-40 ~ +85,10 ~ 95%RHTemp. Coefficient:0.03%/(0 ~ 50)Safety & EMC:Compliance to UL60950-1,EN60950-1Compliance to EN55022(CISPR22) Class BCompliance to EN61000-3-2,-3CE FCCCompetitive Advantage:UniversalAcinput/FullRangeProtections:Shortcircuit/overload/OvervoltageCoolingbyfreeairconvectionLEDindicatorforpoweron100%fullloadburn-intestAllusinglonglifeelectronlyticcapacitorsWithstand300VACsurgeinputfor5secondWithstand5GvibrationtestNoladpowerconsumption<0.5WHigheffciency,longlifeandhighreliability3YearwarrantyApplication: ADXX/Advertising machine power adaptershelter camera adapterLED street lamp power adapterNetwork router power adapterphone program-controlled deviceMedical power supplywave soldering equipment power supplyTelecom equipments power supplyGSM alarm system adapterintercom system adapterData sheet Spec:--------INPUT|Voltage|90-264VAC universal full range|Frequency|47-63Hz|Current|0.5A100V AC input, full load condition|Inrush Current|40A115V , 60A230V AC input.Cold start at 25 ambient|Leakage Current|0.5A 264V AC input|OUTPUT|Voltage|5V|12V|24V|Output Tolerance|5%|5%|5%|Ripple Noise(MAX)|50mV|120mV|200mV|Efficiency(MIN)|75%|85%|85%|Output MAX|24W|24W|24W|PROTECTION|Over Voltage|over 120%150 max|Shutdown and latch off, recover after re-start up|Over Load &Short Circuit|When power supply over 105%150 max load or short circuit acted,powr supply will be shutdown and recover automatically after the fault is removed|Over Temperature|Over 95,the power supply will shutdown.|ENIRONMENT|Temperature|Operating:-2070;De-rating:4570:2.5%/;Storage:-40+85|Humidity|Operating: 20%90% RH(non condensing);Storage:10%95% RH(non condensing)|SAFETY|Withstand voltage|I/P-O/P:3KVAC,I/P-PE:1.5KVAC,O/P-PE:0.5KVAC,1 minute|Isolation resistance|I/P-O/P,I/P-FG,O/P-FG>100M/500VDC at 25/70% RH|Safety standard|UL 60950-1 2nd,CSA C22.2 No.60950-1-07 2nd,TU EN 60950-1:2006,IEC 60950-1:25005,standard|EMC|EMI|EN 55022 CLASS B,FCC CFR 47 PART 15 CLASS B,CNS 13438 CLASS B|Compliance to EN61000-3-2 CLASS D,EN61000-3-3|EMS|EN55024:EN61000-4-2,3,4,5,6,8,11|OTHERS|Cooling|Natural Cooling|M.T.B.F.|100K hours|Dimension|84x58x32mm ( L*W*H )|Packing|N.W.:70g/1pc; 15pcs/1.05kg CUFT/1 CTN|----|----Mechanical spec

