110~220KV XLPE Insulated High Voltage Cable

 
 
单价 面议对比
询价 暂无
浏览 410
发货 China(Mainland)付款后3天内
过期 长期有效
更新 2014-03-14 12:02
 
联系方式
加关注0

HEBEI NEW BAOFENG WIRE & CABLE COMPANY LTD

VIP会员第12年
资料未认证
保证金未缴纳
详细说明

High-voltage 110~220KV XLPE Cable Brief introduction of the 110~220KV XLPE high-voltage cable products: 1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC sheathed power cable. ---- Type | YJLW02, YJLLW02 | Specification | 240mm2~3000mm2 | Voltage | 110~220KV | Usage | Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure. | ---- 2.The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PE sheathed power cable. ---- Type | YJLW02, YJLLW02 | Specification | 240mm2~3000mm2 | Voltage | 110~220KV | Usage | Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure. | ---- Specific property for usage of 110KV~220KV XLPE high-voltage cable: 1. Cables conductor highest working temperature is allowed up to 90, and overload when meet an emergency is 130 , When short circuit (in 5 seconds) the highest temperature is 250 2. When installing or laying cable, the ambient temperature should be less than -20, and have to give a preheat to cable. 3. The minimum bending diameter: ---- Cable type Bending diameter | Metal sheathed | After laying | 30D0 | During laying | 40D0 | ---- Note: In form, D0 is a real test value to cables outer diameter. 4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) T=Kcore NO. section (kg), in formula, the coefficient K value should be: the copper core get 7, the aluminum core get 4. 5. Allowed biggest lateral-press P, when cable is being bent The single core cable is required P500kg/m. P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened. 6. Cable laying is not being restricted by drop.

举报收藏 0
更多>本企业其它产品
High Voltage Waterproof Sheathed Power Cable 64 /110KV, Hig One Step Method Silane XL Cable, Water-proof, Termite-proof Combustion-retardant Wire & Cable Serial Products Special C Heat-resistance Fire-proof Cable Special Cable Used for Pow Plastic Insulated Control Special Cable 450 / 750V D.C. Res
Home  |  Terms & Conditions  |  About us  |  Contact us  |  Agreement  |  隐私政策  |  Copyright Policy  |  Sitemap  |  Promotion  |  Advertisement  |  Gift  |  Guestbook  |  RSS  |  Report  |  浙ICP备2022009825号-2