IEC 62067 High Voltage Power Cable Insulation Electrical Wi

 
 
单价 面议对比
询价 暂无
浏览 390
发货 China(Mainland)付款后3天内
过期 长期有效
更新 2014-03-14 12:11
 
联系方式
加关注0

HENAN XUCHANG SUNLIGHT ELECTRIC AND OPTICAL CABLES & WIRES CO., LTD.

VIP会员第12年
资料未认证
保证金未缴纳
详细说明

IEC 62067 High Voltage Power Cable Insulation Electrical Wires 110kv QuickDetail: ---- InsulationMaterial | XLPE | Type | HighVoltage | Application | Underground | ConductorMaterial | Copper | Jacket | PVC | Character | waterblock | ---- Description: XLPE-insulated power cables for rated voltage 110kV should perform the rules of XLPE-insulated Power Cable for Cable for Rated Voltage 110kV and its attachments in GB/T 11017-2002, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840:1999. XLPE-insulated power cables for rated voltage 220kV should perform the rules of XLPE-insulated Power Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 18890-2002, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV up to 500kV in IEC 62067:2001. XLPE-insulated power cables for rated voltage 500kV should perform the rules of XLPE-insulated Power Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 22078-2008, which is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV up to 500kV in IEC 62067:2006. XLPE-insulated power cables for rated voltage 66kV should perform The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840:1999. MainPerformance 1.TheratedvoltageU0/Uofcables:38/66kV,48/66kV,max.voltageUm=72.5kV; 64/110kV,max.voltageUm=126kV; 127/220kV,maxvoltageUm=252kV; 290/500kV,maxvoltageUm=550kV; 2.permissiblelong-termworkingtemperatureofcableconductor:90; 3. When the cable confronts short circuit within 5 seconds, the highest temperature of conductor should not exceed 250. When there exits line joints, the temperature of tin soldering ones should not exceed 120, the temperature of crimping ones should not exceed 150, and the temperature of electric or gas welding should not exceed 250 4. When laying, the permissible bending radius should exceed 25 times of the out diameter of the cables. After laying, the permissible bending radius should exceed 23 times of the out diameter of the cables. 1.When laying, ambient temperature0(when the cable has to be laid under the ambient temperature below 0,it is necessary to preheat the cable above 0) 2.When laying, the cable is not limited by disparity with the satisfaction of mechanical pressure, but it is not permissible to lay the cable in the iron pipe, nor the circular iron materials around fixed cables. Applications: thetype,name,andsuitableareas ---- type | Description | Suitablefor | Copper-conductor | AL-conductor | YJV,YJY | YJLV,YJLY | XLPEinsulatedPVC/PE sheathedpowercable | Installationinthetube, channelorinair, resistantcertaintension | YJSAV-Z | YJLSAV-Z | Verticalwaterpowercables withXLPE-insulated, copperwireshielded, Al-plasticcompositetape andPVCjacked | Installationinthetube, orchannelresistantthedamp environment andcertaintension | YJSAY-Z | YJLSAY-Z | Verticalwaterpowercables withXLPE-insulated, copperwireshielded, Al-plasticcompositetapeandPEjacked | YJLW02-Z | YJLLW02-Z | Verticalwaterpowercables withXLPE-insulated, corrugatedaluminumandPVCjacked | Tunnelorpipeline, moistplaceslikehigherwaterlevel underground, goodcapacityof anti-moisture andcertainpressure available; speciallyusedintheplaces withlowcorrosionand bearingcertainmechanicalforce (suchasbridge,verticalwell andsoonwiththedirectconnection totransform);PEjackedwithgood capacityofanti-moisture. | YJLW03 | YJLLW03 | Verticalwaterpowercables withXLPE-insulated, corrugatedaluminumandPEjacked | YJQ02-Z | YJLQ02-Z | Verticalwaterpowercables withXLPE-insulated, leadsetandPVCjacked | Tunnelorpipeline, moistplaceslikehigherwater levelunderground, certaintensionandshockresistant; speciallyusedintheplaceswith heavycorrosion butwithoutnitricacid, aceticacid, organicmatter(e.g.peat), andstrongalkalicorrosionquality; certainmechanicalforce (tension,pressure,shock)available; PEjackedwithgoodcapacityof anti-moisture. | YJQ03-Z | YJLQ03-Z | Verticalwaterpowercables withXLPE-insulated, leadsetandPEjacked | ---- Note: 1.The table only lists the main types. According to the requirements if clients, the types of flame-resistant, rat proof, termite proof and so on , can also be produced, then the prefix of ZC, FS, FY should be added. Specifications: ---- Type | UO/URatedvoltage | Numberofcores | Nominalcross-sectionmm2 | YJV,YJLV,YJY,YJLY YJSAV-Z,YJSAV-Z YJSAY-Z,YJLSAY-Z YJLW02-Z,YJLLWO2-Z YJLW03-Z,YJLLW03-Z YJQ02-Z,YJLQ02-Z YJQ03-Z,YJLQ03-Z | 38/6648/66 |

举报收藏 0
更多>本企业其它产品
Copper Conductor Heavy duty Armoured Medium Voltage Power C 600 / 1000v 4 Core Low Voltage PVC-Insulated Electrical Pow High Voltage Power Cable Electricity Underground Cables Sin PVC Insulated Cable Four Conductor Cable 600 / 1000v  Elect Safety Copper Conductor Low Voltage Power Cable Insulation 600 / 1000v 4 Cores Low Voltage PVC Insulated PVC Sheathed IEC 60502 Armour Cables with PVC Jacket XLPE Insulated Powe
Home  |  Terms & Conditions  |  About us  |  Contact us  |  Agreement  |  隐私政策  |  Copyright Policy  |  Sitemap  |  Promotion  |  Advertisement  |  Gift  |  Guestbook  |  RSS  |  Report  |  浙ICP备2022009825号-2