AI-1 Infant Incubator (Top Grade)

 
 
单价 面议对比
询价 暂无
浏览 851
发货 China(Mainland)付款后3天内
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
过期 长期有效
更新 2014-03-15 11:28
 
联系方式
加关注0

ARI MED CO.,LTD

VIP会员第12年
资料未认证
保证金未缴纳
  • China(Mainland)
  • 上次登录 2014-03-15
  • Wang Junchao(Sales D (女士)  
详细说明

AI-1 infant incubator (Top grade)Function features: 1. Microprocessor based servo controlled temperature system2. Temperature displayed by LED3. Alarms functions: Power failure; Over temperature; Temperature deviation; Temperature sensor failure; Fan failure; 4. >37deg C temperature setting5. A keypad lock prevent inadvertent changes the setting 6. Humidity is adjustable continuously7. Heating power displayed on panel8. A second thermal cut-off function for more safety9. The infant bed inclination angle is adjustable10. Trough for pulling and pushing, which is convenient to add water and wash 11. Fan with low noise and long life-span12. Temperature deviation and over temperature could be amended in front panel directly13. Silence/reset button for alarms14. Six operating windows, two sides operating windows can be swiveled15. Heater is electrically cut-out if air temperature inside incubator exceed 40 deg; C16. Cupboard for easy storageStandard configuration: Main body(including the transparent hood, control system, infant bed, water trough), I. V. Pole, mattress, cabinet, castors. Optional parts: --Phototherapy up side unit; --phototherapy from up and down sides; --RS232(485)conncector; Tray/pole; --Infant bed pulled from side door; --Infant bed pulled from side and front door; --Double wall hood. Technical data: -- Power supply: AC 110/220V 60/50Hz-- Power input: >=420VAOperating conditions: -- Environment temperature: 20 C~30 C-- Environment relative humidity: 30%~75%RH -- Environment air velocity of flow: <0.3m/s-- Humidity accuracy: <=10%RH -- Air Temperature control range: 25deg; C~38deg; C-- Temperature fluctuation: +0.5 deg; C-- Uniformity of mattress temperature: <= 0.8deg; C-- Warm-up time: <=45min -- Internal noise level: <=55dB-- Infant bed tilt angle: +10 degree -- Mattress size: 65cm(L)x37cm(W)-- Trough capacity: 1200ml -- Air filter: 0.5umPackage: Each unit is packed in two wooden crate-- Size (control unit and cabinet): 120*70*96cm N. W.: 80Kg G. W.: 110Kg-- Hood: 97*56*63cm N. W.: 15Kg G. W.: 40KgTransport and storage: Environment Temp: -10 deg; C--+70 deg; CEnvironment Relative Humidity: <=80%Atmospheric Pressure: 500-1060Hpa Trademark: ARIMED Origin: China Company: Ari Med Co., Ltd.

举报收藏 0
更多>本企业其它产品
ARI II Colposcope AL-5 Infant Phototherapy Unit ARI-3000 Mammography System Full Digital Color Doppler Ultrasound Diagnostic System (AR-380)
Home  |  Terms & Conditions  |  About us  |  Contact us  |  Agreement  |  隐私政策  |  Copyright Policy  |  Sitemap  |  Promotion  |  Advertisement  |  Gift  |  Guestbook  |  RSS  |  Report  |  浙ICP备2022009825号-2