Popularize Hot: rack  Necklace  forging  bitumen  led  aluminum  tools  abrasives  hoe  hinge 

TSA6000 Compact Fully Automated Coagulation Analyzer

Click to view the original image
 
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Unit Price: negotiate face to face
Min.Order:
Supply:
Delivery: Shipment within 3 days since the date of payment
Address: China(Mainland)
Valid until: Never Expire
Updated on: 2014-03-15 12:07
Hits: 518
Enquiry
 
Company Details
Details

TSA6000 Compact Fully Automated Coagulation Analyzer

Internationally recognized methodology

Effective and reliable detection

Original set of reagents

Emergency priority functions

Two-way data transmission

Scientific management information

TECHNIQUE REFERENCES

Detection system

Detection method: Freezing method, optional chromogenic substrate immunoturbidimetry

Detection speed: An average of 200tests/h for single item

Accuracy: +/-3%

Error of repeatability: </=3%

Systematical control

Sample handling needle: Sample handling and reagent needles with Sensors, reagent needle can be controlled at a constant temperature

QC system: User-definable quality control procedures, quality control Standards for the provision of documents and charts.

Other:

Reagent with automatic dilution, two-reagent Automatic switch to support the copy operation.

Loading capacity

Sample position: 61 (with original tube for direct insertion)

Reagebt Position: 10 (refrigeration)

Cuvettes: 1000 cuvettes with stainless steel ball

Operating requirements

Dimensions: 695*580*595mm

Weight: 60kg

Voltage: (220+/-22)V, frequency (50+/-1)Hz

Environmental temperature: 10-30ceti degree

Relative temperature: </=70%

Atmospheric pressure: 700hpa~1060hpa

No interference from electromagnetism, vibration, conduction dust and corrosive gas

Principal tests

Prothrombin time

Activated partial thromboplastin time

Fibrinogen

Coagulation factors (Factors II, V, VII, IX, X, XI, XII)

Thrombin time

Protein S

Protein C

Heparin

Lupus anticoagulant

Antithrombin III

Fibrin degradation product

D-Dimer

Features

Testing or specimens testing

1. Advanced laboratory reagent and consumables management.

2. Complete management of quality control and automatic calibration.

3. Automatic sample handling and detection

4. Automatic generation of test reports according to the setting of user

5. Automatic sample handling and testing of emergency record for the priorities

6. Support auto-pilot error report of the process and appropriate measures

7. Test temperature can be controlled and displayed automatically

Detection Method

Internationally recognized theory of double-track beads

No interference from turbid samples in optical method

No interference from chyle, jaundice and hyperlipemia

No interference from air bubbles produced during sample handing

Information Processing System

Powerful software operating system

l Easy setting of testing item portfolio in accordance with diagnosis needs

l Function of automatic dilution, automatic and manual detection

l Priority processing and no suspension of running test while emergency samples handing

l English version easy for various hospital with different levels

Intelligent and whole controlling system

l Closed structure, keeping refrigerated reagent at 15°C and detection area at 37°C

l Whole controlling of sample running, amount of reagents and consumables, sample handing and cleaning system, etc

l Completion of sample handing, prewarming, testing and printing after putting the sample

l Features tips for shortage of reagent and cuvette

Quality control system

l Conduction of quality control testing and analysis at anytime

l Complete settings and measurements of standard curve, describe standard curve automatically

l Sweep the calibration curves of PT and FIB into computer, save reagents and reference object accurately

l User can choose the method of calibrating the reference object and reagents

Sample/Reagent Management

l 10 reagent refrigeration positions, 2 reagent agitation positions

l 61 sample positions to meet the demand for development of specimen volume

l Read information such as reagent name, lot, volume time and stability

l Usage of original test-tube, vacuum vessel and small sample test-tube

Reagent

l Matching reagents, quality control, reference object and consumables for the most accurate results

l Calculating the amount of reagent automatically according to the current requirements for the number of test samples, avoiding interruption

l Instruments open for other reagents completely

Measurement & Detection System

l Intelligent robot sensors crawling cuvette in a row running

l Effective avoidance of reagents and samples cross-infection by independent needles

l Reagent needle with automatic heating function, prewarm the low temperature preservation reagent to 37°C in 2 seconds

l Needles with automatic liquid level detection function and accurate alarm function for samples of the liquid level Technique references

Adopt high-voltage pulse-washing method internal and external synchronization washing

Reduce the rate of cross-contamination

More>Our Others Products
TSA6000 Compact Fully Automated Coagulation Analyzer
Home  |  Terms & Conditions  |  About us  |  Contact us  |  Agreement  |  Copyright Policy  |  Sitemap  |  Ranking promotion  |  Advert Server  |  Integral Exchange  |  Guestbook  |  RSS  |  Whistle-blowing