Multi Core 1.8 / 3KV Low Votage PVC Insulated Cable / Armoured Cabling Specifications PVC-Insulated Cables 1.High Degree Copper Conductor 2.Durable outer Sheath 3.Quick Delivery & Reliable Quality 4.CCC Honor PVC-Insulated Cables Model No : W22.5*16 Low Votage VV 1. The cablewas suitable forAC rated voltage not exceeding 3.6/6KV. 2. All the characteristics & Technologyarereferenced by A:NationalStandardGB/T12706-2008 B: International Standard IEC60502-1:2004,60502-2:2005 3.The Sheathing Insulated Power Cables with the Rated Voltage 1kv to 35kv and Its Attachment The sue characteristic &index of electrical characteristics: # A.Suitable installation temperature:0C # B.Regular working temperature of conductor:70C # C.Under the condition of short circuit(the max. # continuing time should not exceeding 5 seconds) the max. # operation temperature:160C # D.the permissible minimum bending radius: # single core:20D multicore: 20D E:The Following Tested cables of the Ac Votage ---- KV Rated voltage | 0.6/1| 1.8/3| 3.6/6| KV Test voltage | 3.5| 6.5| 12.5| min Continuing time(min.) | 5| 5| 5| ---- F: The DCR of conductor comply with the rules of GB/T3956-2008 The Conductor of Cables ---- Type | | Name| Suitable Range| Copper-Conductor | Aluminum-Conductor | | | VV | VLV | PVC insulated and sheathed power cable | Installation in such place as indoor, tunnel, pipeline, cable channel, and flammable and deep-corrosion areas; the mechanical force is unavailable| VY| VLY| PVC insulated and sheathed power cable | Installation in such place as indoor, tunnel, pipeline, cable channel, and flammable and deep-corrosion areas; the mechanical force is unavailable| VV22| VLV22| insulated and sheathed cable with copper tape | Installation in such place as indoor, cable channel, underground and deep-corrosion areas; the lager tension is unavailable. | VV23| VLV23| PVC insulated and sheathed cable with steel tape | Installation in such place as indoor, cable channel, underground and deep-corrosion areas; the lager tension is unavailable. | VV32| VLV32| PVC insulated and sheathed cable armored with thin steel wire | Installation in such place as underground, vertical shaft, water and deep-corrosion areas; the lager tension is unavailable. | VV33| VLV33| PVC--insulted and polythenesheathed cables armored with thin steel wire | Installation in such place as underground, vertical shaft, water and deep-corrosion areas; the lager tension isunavailable| VV42| VLV42| PVC insulated and sheathed cable armored with thick steel wire | Installation in such place as underground,vertical shaft, water and deep-corrosion areas; the lager tension isunavailable. | VV43| VLV43| PVC--insulted and polythenesheathed cables armored with thick steel wire | Installation in such place as underground,vertical shaft, water and deep-corrosion areas; the lager tension isunavailable| ---- The Framework of our Management: The Main Process of Production : The finished goods with packaged :